Virtual Port Mode — One Fibre Channel Fabric with Dual 16 Gb 2-Port Storage Controllers
Use one Fibre Channel (FC) fabric with virtual port mode to prevent an unavailable port or storage
controller from causing a loss of connectivity between the host servers and a storage system with dual 16
Gb 2-port
storage controllers.
About this task
This configuration includes one fault domain, one fabric, and one FC switch. Each storage controller
connects to the FC switch using two FC connections.
If a physical port becomes unavailable, the virtual port moves to another port in the fault domain on
the same storage controller
If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to
physical ports on the other storage controller.
NOTE: This configuration is vulnerable to switch unavailability, which results in a loss of connectivity
between the host servers and
storage system.
Steps
1. Connect each server to the FC fabric.
2. Connect fault domain 1 (shown in orange) to the fabric.
Storage controller 1: port 1 to the FC switch
Storage controller 1: port 2 to the FC switch
Storage controller 2: port 1 to the FC switch
Storage controller 2: port 2 to the FC switch
Example
Figure 46. Storage System in Virtual Port Mode with Dual 16 Gb Storage Controllers and One FC Switch
1. Server 1 2. Server 2
3. FC switch (Fault domain 1) 4. Storage system
5. Storage controller 1 6. Storage controller 2
Next steps
Install or enable MPIO on the host servers.