Chapter 6 Control Modes of Operation|ASDA-AB Series
6-22 Revision January 2009
In theory, stepping response can be used to explain proportional gain (KVP), integral gain (KVI) and
feed forward gain (KVF). Now we use frequency area and time area respectively to explain the logic.
Frequency Domain