Chapter 7 Servo Parameters|ASDA-AB Series
7-10
Revision January 2009
Smooth Filter and Resonance Suppression
Control
Mode
Parameter Name Function Default Unit
Pt Pr S T
Related
Section of
User
Manual
P1-06 SFLT
Accel / Decel Smooth Constant of
Analog Speed Command (Low-
pass Filter)
0 ms
{
6.3.3
P1-07 TFLT
Smooth Constant of Analog Torque
Command (Low-pass Filter)
0 ms
{
6.4.3
P1-08 PFLT
Smooth Constant of Position
Command (Low-pass Filter)
0 ms
{
6.2.6
P1-34 TACC Acceleration Time 200 ms
{ {
6.3.3
P1-35 TDEC Deceleration Time 200 ms
{ {
6.3.3
P1-36 TSL Accel /Decel S-curve 0 ms
{ {
6.3.3
P2-23 NCF
Notch Filter (Resonance
Suppression)
1000 Hz
{ { { {
6.3.7
P2-24 DPH
Notch Filter Attenuation Rate
(Resonance Suppression)
0 dB
{ { { {
6.3.7
P2-25 NLP
Low-pass Filter Time Constant
(Resonance Suppression)
2 or 5 ms
{ { { {
6.3.7
P2-33
INF
Easy Setting of Input Filter
0 N/A
{ { { {
6.3.6
P2-49 SJIT
Speed Detection Filter and Jitter
Suppression
0 sec
{ { { {
---
Explanation of symbols (marked after parameter)
() Read-only register.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and on).
() Parameter setting values are not retained when power is off.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics AC Servo Drive ASDA-AB and is the answer not in the manual?

Delta Electronics AC Servo Drive ASDA-AB Specifications

General IconGeneral
BrandDelta Electronics
ModelAC Servo Drive ASDA-AB
CategoryDC Drives
LanguageEnglish

Related product manuals