Chapter 7 Servo Parameters|ASDA-AB Series
Revision January 2009 7-7
Group 3: P3-xx
Communication Parameters
Control
Mode
Parameter Name Function Default Unit
Pt Pr S T
P3-00 ADR Communication Address Setting 1 N/A
{ { { {
P3-01 BRT Transmission Speed 1 bps
{ { { {
P3-02 PTL Communication Protocol 0 N/A
{ { { {
P3-03 FLT Transmission Fault Treatment 0 N/A
{ { { {
P3-04 CWD Communication Time Out Detection 0 sec
{ { { {
P3-05 CMM Communication Selection 0 N/A
{ { { {
P3-06
SDI
Digital Input Communication Function
0 N/A
{ { { {
P3-07 CDT Communication Response Delay Time 0 0.5ms
{ { { {
Explanation of symbols (marked after parameter)
() Read-only register.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and on).
() Parameter setting values are not retained when power is off.