Chapter 7 Servo Parameters|ASDA-AB Series
Revision January 2009 7-23
P0 - 05 CM2 Status Monitor 2 Communication Addr.: 0005H
Default: 0 Related Section:
Applicable Control Mode: ALL Section 4.3.5
Unit: N/A
Range: 0 ~ 16
Settings: See P0-04 for explanation.
P0 - 06 CM3 Status Monitor 3 Communication Addr.: 0006H
Default: 0 Related Section:
Applicable Control Mode: ALL Section 4.3.5
Unit: N/A
Range: 0 ~ 16
Settings: See P0-04 for explanation.
P0 - 07 CM4 Status Monitor 4 Communication Addr.: 0007H
Default: 0 Related Section:
Applicable Control Mode: ALL Section 4.3.5
Unit: N/A
Range: 0 ~ 17
Settings:
Select the desired drive status through communication setting or the keypad (please refer to P0-
02). The drive status can be read from the communication address of this parameter via
communication port. If users set this parameter to 17, the status of DI signal can be read.
P0 - 08 CM5 Status Monitor 5 Communication Addr.: 0008H
Default: 0 Related Section:
Applicable Control Mode: ALL Section 4.3.5
Unit: N/A
Range: 0 ~ 17
Settings:
Select the desired drive status through communication setting or the keypad (please refer to P0-
02). The drive status can be read from the communication address of this parameter via
communication port. If users set this parameter to 17, the status of DO signal can be read.