Chapter 8 ParametersASDA-A2R Series
8-84 Revision December, 2014
Data Size
16bit
Format
DEC
Settings
When the speed control command runs smoothly, increasing the
gain value can reduce the speed command error. If the command
does not run smoothly, decreasing the gain value can reduce the
mechanical vibration during operation.
P2-08
PCTL Special Parameter Write-in
Address: 0210H
0211H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 65535
Data Size
16bit
Format
DEC
Settings
Special parameter write-in:
Parameter
code
Function
10
Reset the parameter (Apply to the power
again after reset)
20 P4-10 is writable
22 P4-11~P4-19 are writable
30,35
Save the data of COMPARE, CAPTURE,
E-Cam
406 Enable forced DO mode
400
When forced DO mode is enabled, it can
switch back to the normal DO mode.
P2-09 DRT DI Debouncing Time
Address: 0212H
0213H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
2
Control
Mode
ALL
Unit
2ms
Range
0 ~ 20