Chapter 8 ParametersASDA-A2R Series
Revision December, 2014
8-153
P5-32 AC12
Acceleration/Deceleration Time (Number
#12)
Address: 0540H
0541H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
5000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit
Format
DEC
Settings
Please refer to P5-20 for the setting of acceleration/deceleration
time in PR mode.
P5-33 AC13
Acceleration/Deceleration Time (Number
#13)
Address: 0542H
0543H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
8000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit
Format
DEC
Settings
Please refer to P5-20 for the setting of acceleration/deceleration
time in PR mode.
P5-34 AC14
Acceleration/Deceleration Time (Number
#14)
Address: 0544H
0545H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
50
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit

Table of Contents