Chapter 8 ParametersASDA-A2R Series
8-154 Revision December, 2014
Format
DEC
Settings
The default value of this parameter is smaller (short deceleration
time) and it is used for deceleration time setting of auto protection.
P5-35 AC15
Acceleration/Deceleration Time (Number
#15)
Address: 0546H
0547H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
30
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit
Format
DEC
Settings
The default value of this parameter is smaller (short deceleration
time) and it is used for short deceleration time and stops promptly
of auto protection.
P5-36 CAST CAPTURE - Start Address of Data Array
Address: 0548H
0549H
Operational
Interface
Panel / Software Communication
Related Section:
7.11.1
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ (value set by P5-10 minus 1)
Data Size
16bit
Format
DEC
Settings
The first data CAPTURE obtained should be saved in the address
of data array.
NOTE
It is writable only when COMPARE stops (please refer to P5-39)