ASDA-M Chapter 5 Trial Operation and Tuning
Revision December, 2014 5-5
6) When the screen displays
Warning of overcurrent:
Corrective action:
Check the connection between the motor and servo drive.
Check if the conducting wire is short circuited.
Exclude short circuit and avoid metal conductors being exposed.
7) When the screen displays
Warning of under voltage:
Corrective action:
Check if the wiring of main circuit input voltage is correct.
Use voltmeter to measure if the main circuit voltage is normal.
Use voltmeter to measure if the power system complies with the specification.
Note: During the process of power on or servo on, if an alarm occurs or shows any
abnormal display, please contact the distributors.