ASDA-M Chapter 8 Parameters
Revision December, 2014 8-53
P1-20
Reserved
Address: 0128H
0129H
P1-21
Reserved
Address: 012AH
012BH
P1-22
Reserved
Address: 012CH
012DH
P1-23
Reserved
Address: 012EH
012FH
P1-24
Reserved
Address: 0130H
0131H
P1-25
VSF1
Low-frequency Vibration Suppression
(1)
Address: 0132H
0133H
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 6.2.9
Operational
Interface:
Panel / Software Communication
Default:
1000
Control
Mode:
PT / PR
Unit:
0.1 Hz
Range:
10 ~ 1000
Data Size:
16bit
Format:
DEC
Example:
150= 15 Hz
Settings:
The setting value of the first low-frequency vibration suppression.
If P1-26 is set to 0, then it will disable the first low-frequency filter.
P1-26
VSG1
Low-frequency Vibration Suppression
Gain (1)
Address: 0134H
0135H
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 6.2.9
Operational
Interface:
Panel / Software Communication
Default:
0
Control
Mode:
PT / PR