ASDA-M Chapter 8 Parameters
Revision December, 2014 8-83
P2-08
PCTL Special Parameter Write-in
Address: 0210H
0211H
Parameter
Attribute
Parameter for three axes
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 65535
Data Size
16bit
Format
DEC
Settings
Special parameter write-in:
Parameter
code
Function
10
Reset the parameter for individual axis (Apply
to the power again after reset)
11
Reset the parameter for three axes (Apply to
the power again after reset)
20 P4-10 is writable
22 P4-11~P4-19 are writable
30,35
Save the data of COMPARE, CAPTURE,
E-Cam

Table of Contents