ASDA-M Chapter 8 Parameters
Revision December, 2014 8-93
P2-26 DST Anti-interference Gain
Address: 0234H
0235H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
1
Range
0 ~ 1023 (0: disable this function)
Data Size
16bit
Format
DEC
Settings
Increasing the value of this parameter can increase the damping
of speed loop. It is suggested to set P2-26 equals to the value of
P2-06. If users desire to adjust P2-26, please follow the rules
below.
1. In speed mode, incrase the value of this parameter can
reduce speed overshoot.
2. In position mode, decrease the value of this parameter can
reduce position overshoot.
P2-27 GCC Gain Switching and Switching Selection