ASDA-M Chapter 8 Parameters
Revision December, 2014 8-95
Control
Mode
ALL
Unit
10ms
Range
0 ~ 1000
Data Size
16bit
Format
DEC
Example
15 = 150 ms
Settings
It is for switching the smooth gain. (0: disable this function)
P2-29 GPE Gain Switching
Address: 023AH
023BH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
1280000
Control
Mode
ALL
Unit
Pulse, Kpps, r/min
Range
0 ~ 3840000
Data Size
32bit
Format
DEC
Settings
The setting of gain switching (Pulse error, Kpps, r/min) is
determined by the selection of gain switching (P2-27).
P2-30
INH Auxiliary Function
Address: 023CH
023DH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
-
Range
-8 ~ +8
Data Size
16bit

Table of Contents