ASDA-M Chapter 8 Parameters
Revision December, 2014 8-145
P5-05 HSPD1
1
st
Speed Setting of High Speed
Homing
Address: 050AH
050BH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
100.0 1000
Control
Mode
ALL
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 2000.0 1 ~ 20000
Data Size
16bit
Format
DEC
Example
1.5 = 1.5 r/min 15 = 1.5 r/min
Settings
The 1
st
speed of high speed homing
P5-06 HSPD2
2
n
d
Speed Setting of Low Speed
Homing
Address: 050CH
050DH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
20.0 200
Control
Mode
ALL
Unit
1 r/min 0.1 r/min
Range
1 ~ 500.0 10 ~ 5000
Data Size
16bit
Format
DEC
Example
15 = 15 r/min 150 = 15 r/min