7 Application Instructions API 50-99
DVP-PLC APPLICATION MANUAL
7-84
Register Data Explanation
D123 high ‘0’ 30 H
D124 low ‘1’ 31 H
D124 high ‘0’ 30 H
D125 low ‘0’ 30 H
Content of address 2101 H
D125 high ‘1’ 31 H
D126 low ‘7’ 37 H
D126 high ‘6’ 36 H
D127 low ‘6’ 36 H
Content of address 2102 H
D127 high ‘0’ 30 H
D128 low ‘0’ 30 H
D128 high ‘0’ 30 H
D129 low ‘0’ 30 H
Content of address 2103 H
D129 high ‘0’ 30 H
D130 low ‘0’ 30 H
D130 high ‘0’ 30 H
D131 low ‘0’ 30 H
Content of address 2104 H
D131 high ‘0’ 30 H
D132 low ‘1’ 31 H
D132 high ‘3’ 33 H
D133 low ‘6’ 36 H
Content of address 2105 H
D133 high ‘0’ 30 H
D134 low ‘0’ 30 H
D134 high ‘0’ 30 H
D135 low ‘0’ 30 H
Content of address 2106 H
D135 high ‘3’ 33 H
LRC CHK 1
D136 low ‘B’ 42 H
LRC CHK 0
D136 high CR D H
D137 low LF A H
END
Program Example 4:
Connect PLC to VFD-B series AC motor drives (AC motor drive in RTU Mode; PLC in 16-bit mode and M1161 = On).
Write in H12 to parameter address H2000 in VFD-B in advance as the data to be transmitted.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-PLC and is the answer not in the manual?

Delta DVP-PLC Specifications

General IconGeneral
ManufacturerDelta Electronics
ModelDVP-PLC
CategoryController
Humidity5% to 95% RH, non-condensing
Programming LanguageLadder Diagram (LD), Instruction List (IL), Sequential Function Chart (SFC)
CPU TypeVarious, depending on the specific model within the DVP series (e.g., ES2, EX2, SX2, SA2, EH3, etc.)
Operating TemperatureTypically 0°C to 55°C (32°F to 131°F)
Storage TemperatureTypically -25°C to 70°C (-13°F to 158°F)

Related product manuals