9 Application Instructions API 150-199
DVP-PLC Application Manual
9-63
API Mnemonic Operands Function
183
MXNR P
Matrix ‘XNR’ Operation
Controllers
ES/EX/SS SA/SX/SC EH/SV
Bit Devices Word Devices Program Steps Type
OP
X Y M S K H KnX KnY KnM KnS T C D E F
S
1
* * * * * * *
S
2
* * * * * * *
D * * * * * *
n * * *
MXNR, MXNRP: 9 steps
PULSE 16-bit 32-bit
ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV
Operands:
S
1
: Matrix source device 1 S
2
: Matrix source device 2 D: Operation result n: Array length
Explanations:
1. Range of n: K1 ~ K256
2. S
1
, and S
2
designate KnX, KnY, KnM and KnS; D designates KnYm KnM and KnS
3. SA/SX/SC can designate n = 4. EH/EH2/SV can designate n 4 .
4. See the specifications of each model for their range of use.
5. The two matrix sources S
1
and S
2
perform matrix ‘XNR’ operation according to the array length n. The result is
stored in D.
6. Operation rule of matrix ‘XNR’: The result will be 1 if the two bits are the same. The result will be 0 if the two bits
are different.
Program Example:
When X0 = On, the 3 arrays of 16-bit registers D0 ~ D2 and the 3 arrays of 16-bit registers D10 ~ D12 will perform a
matrix ‘XNR’ operation. The result will be stored in the 3 arrays of 16-bit registers D20 ~ D22.
X0
MXNR D0 D10 D20 K3
Before
Execution
After
Execution
1
11
000
11
0000
11000
11
0000
11000
11
0000
010101010101010
1010101010101010
1010101010101010
1
1
1
1
1
1
0
0
0
1
1
1
1
1
1
1000
1
000
1000
1
1
1
11
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
b15 b0
MXNR

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-PLC and is the answer not in the manual?

Delta DVP-PLC Specifications

General IconGeneral
ManufacturerDelta Electronics
ModelDVP-PLC
CategoryController
Humidity5% to 95% RH, non-condensing
Programming LanguageLadder Diagram (LD), Instruction List (IL), Sequential Function Chart (SFC)
CPU TypeVarious, depending on the specific model within the DVP series (e.g., ES2, EX2, SX2, SA2, EH3, etc.)
Operating TemperatureTypically 0°C to 55°C (32°F to 131°F)
Storage TemperatureTypically -25°C to 70°C (-13°F to 158°F)

Related product manuals