EasyManuals Logo

Delta DVP-PLC User Manual

Delta DVP-PLC
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #415 background imageLoading...
Page #415 background image
8 Application Instructions API 100-149
DVP-PLC Application Manual
8-13
Registers for received data (responding messages)
Register DATA Explanation
D1070 low ‘C’ 43 H Start word of instruction
D1071 low ’ 03 H Checksum
D1072 low 06 H Reply authorization (correct: 06H, incorrect: 07 H)
D1073 low ‘0’ 30 H
D1074 low ‘0’ 30 H
D1075 low ‘0’ 30 H
D1076 low ‘1’ 31 H
Communication address
D1077 low ‘0’ 30 H
D1078 low ‘5’ 35 H
D1079 low ‘0’ 30 H
D1080 low ‘0’ 30 H
Running instruction
Remarks:
There is no limitation on the times of using this instruction in the program, but only one instruction is allowed to be
executed at a time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-PLC and is the answer not in the manual?

Delta DVP-PLC Specifications

General IconGeneral
ManufacturerDelta Electronics
ModelDVP-PLC
CategoryController
Humidity5% to 95% RH, non-condensing
Programming LanguageLadder Diagram (LD), Instruction List (IL), Sequential Function Chart (SFC)
CPU TypeVarious, depending on the specific model within the DVP series (e.g., ES2, EX2, SX2, SA2, EH3, etc.)
Operating TemperatureTypically 0°C to 55°C (32°F to 131°F)
Storage TemperatureTypically -25°C to 70°C (-13°F to 158°F)