9 Application Instructions API 150-199
DVP-PLC Application Manual
9-29
D1336
For EH/EH2/SV, low word of the current number of output pulses from CH0.
D1337
For EH/EH2/SV, high word of the current number of output pulses from CH0.
D1338
For EH/EH2/SV, low word of the current number of output pulses from CH1.
D1339
For EH/EH2/SV, high word of the current number of output pulses from CH1.
D1340
For EH/EH2/SV, settings of the first start frequency and the last end frequency of CH0.
D1343
For EH/EH2/SV, settings of acceleration/deceleration time for CH0 pulse output.
D1352
For EH/EH2/SV, settings of the first start frequency and the last end frequency of CH1.
D1353
For EH/EH2/SV, settings of acceleration/deceleration time for CH1 pulse output.
D1375
For EH2/SV, low word of the current number of output pulses from CH2.
D1376
For EH2/SV, high word of the current number of output pulses from CH2.
D1377
For EH2/SV, low word of the current number of output pulses from CH3.
D1378
For EH2/SV, high word of the current number of output pulses from CH3.
D1379
For EH2/SV, settings of the first start frequency and the last end frequency of CH2.
D1380
For EH2/SV, settings of the first start frequency and the last end frequency of CH3.
D1348 For EH2/SV, deceleration time for CH0 pulse output when M1534 = On.
D1349 For EH2/SV, deceleration time for CH1 pulse output when M1535 = On.
D1350 For EH2/SV, deceleration time for CH2 pulse output when M1536 = On.
D1351 For EH2/SV, deceleration time for CH3 pulse output when M1537 = On.
D1381 For EH2/SV, settings of acceleration/deceleration time for CH2 pulse output.
D1382 For EH2/SV, settings of acceleration/deceleration time for CH3 pulse output.
D1383 For EH2/SV, the time difference between the direction signal and pulse output sent by CH2.
D1384 For EH2/SV, the time difference between the direction signal and pulse output sent by CH3.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-PLC and is the answer not in the manual?

Delta DVP-PLC Specifications

General IconGeneral
ManufacturerDelta Electronics
ModelDVP-PLC
CategoryController
Humidity5% to 95% RH, non-condensing
Programming LanguageLadder Diagram (LD), Instruction List (IL), Sequential Function Chart (SFC)
CPU TypeVarious, depending on the specific model within the DVP series (e.g., ES2, EX2, SX2, SA2, EH3, etc.)
Operating TemperatureTypically 0°C to 55°C (32°F to 131°F)
Storage TemperatureTypically -25°C to 70°C (-13°F to 158°F)