EasyManuals Logo

Delta DVP-PLC User Manual

Delta DVP-PLC
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-62
Special D Function
ES
EX
SS
SA
SX
SC
EH
EH2
SV
Off
Ø
On
STOP
Ø
RUN
RUN
Ø
STOP
Attribute Latched Default
SC: low word of present value of Y11 pulse output
0 - - R NO 0
D1350
EH2/SV: CH2 pulse output. When M1536 = On, it
refers to the deceleration time
- - - R/W YES 100
SC: high word of present value of Y11 pulse output
0 - - R NO 0
D1351
EH2/SV: CH3 pulse output. When M1537 = On, it
refers to the deceleration time
- - - R/W YES 100
EH/EH2/SV: start/end frequency of the 2
nd
group
pulse output CH1 (Y2, Y3)
- YES
D1352
SC: start/end frequency of Y11 output
200
- - R/W
NO
200
EH/EH2/SV: acceleration/deceleration time of the
2
nd
group pulse output CH1 (Y2, Y3)
- YES 100
D1353*
SC: acceleration/deceleration time of Y11 output
200
- - R/W
NO 200
D1355*
Starting reference for Master to read from Salve
ID#1
- - - R/W
YES
H’1064
D1356*
Starting reference for Master to read from Salve
ID#2
- - - R/W
YES
H’1064
D1357*
Starting reference for Master to read from Salve
ID#3
- - - R/W
YES
H’1064
D1358*
Starting reference for Master to read from Salve
ID#4
- - - R/W
YES
H’1064
D1359*
Starting reference for Master to read from Salve
ID#5
- - - R/W
YES
H’1064
D1360*
Starting reference for Master to read from Salve
ID#6
- - - R/W
YES
H’1064
D1361*
Starting reference for Master to read from Salve
ID#7
- - - R/W
YES
H’1064
D1362*
Starting reference for Master to read from Salve
ID#8
- - - R/W
YES
H’1064
D1363*
Starting reference for Master to read from Salve
ID#9
- - - R/W
YES
H’1064
D1364*
Starting reference for Master to read from Salve
ID#10
- - - R/W
YES
H’1064
D1365*
Starting reference for Master to read from Salve
ID#11
- - - R/W
YES
H’1064
D1366*
Starting reference for Master to read from Salve
ID#12
- - - R/W
YES
H’1064
D1367*
Starting reference for Master to read from Salve
ID#13
- - - R/W
YES
H’1064
D1368*
Starting reference for Master to read from Salve
ID#14
- - - R/W
YES
H’1064

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-PLC and is the answer not in the manual?

Delta DVP-PLC Specifications

General IconGeneral
ManufacturerDelta Electronics
ModelDVP-PLC
CategoryController
Humidity5% to 95% RH, non-condensing
Programming LanguageLadder Diagram (LD), Instruction List (IL), Sequential Function Chart (SFC)
CPU TypeVarious, depending on the specific model within the DVP series (e.g., ES2, EX2, SX2, SA2, EH3, etc.)
Operating TemperatureTypically 0°C to 55°C (32°F to 131°F)
Storage TemperatureTypically -25°C to 70°C (-13°F to 158°F)

Related product manuals