2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-65
Special D Function
ES
EX
SS
SA
SX
SC
EH
EH2
SV
Off
Ø
On
STOP
Ø
RUN
RUN
Ø
STOP
Attribute Latched Default
D1444* Data length to be read on Salve ID#11
- - - R/W YES
16
D1445* Data length to be read on Salve ID#12
- - - R/W YES
16
D1446* Data length to be read on Salve ID#13
- - - R/W YES
16
D1447* Data length to be read on Salve ID#14
- - - R/W YES
16
D1448* Data length to be read on Salve ID#15
- - - R/W YES
16
D1449* Data length to be read on Salve ID#16
- - - R/W YES
16
D1450* Data length to be written on Slave ID#1
- - - R/W YES
16
D1451* Data length to be written on Slave ID#2
- - - R/W YES
16
D1452* Data length to be written on Slave ID#3
- - - R/W YES
16
D1453* Data length to be written on Slave ID#4
- - - R/W YES
16
D1454* Data length to be written on Slave ID#5
- - - R/W YES
16
D1455* Data length to be written on Slave ID#6
- - - R/W YES
16
D1456* Data length to be written on Slave ID#7
- - - R/W YES
16
D1457* Data length to be written on Slave ID#8
- - - R/W YES
16
D1458* Data length to be written on Slave ID#9
- - - R/W YES
16
D1459* Data length to be written on Slave ID#10
- - - R/W YES
16
D1460* Data length to be written on Slave ID#11
- - - R/W YES
16
D1461* Data length to be written on Slave ID#12
- - - R/W YES
16
D1462* Data length to be written on Slave ID#13
- - - R/W YES
16
D1463* Data length to be written on Slave ID#14
- - - R/W YES
16
D1464* Data length to be written on Slave ID#15
- - - R/W YES
16
D1465* Data length to be written on Slave ID#16
- - - R/W YES
16
D1466
Number of pulses required per revolution of motor at
CH0 (low word)
- - - R YES 2,000
D1467
Number of pulses required per revolution of motor at
CH0 (high word)
- - - R YES 0
D1468
Number of pulses required per revolution of motor at
CH1 (low word)
- - - R YES 2,000
D1469
Number of pulses required per revolution of motor at
CH1 (high word)
- - - R YES 0
D1470
Distance created for 1 revolution of motor at CH0
(low word)
- - - R YES 1,000
D1471
Distance created for 1 revolution of motor at CH0
(high word)
- - - R YES 0
D1472
Distance created for 1 revolution of motor at CH1
(low word)
- - - R YES 1,000

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-PLC and is the answer not in the manual?

Delta DVP-PLC Specifications

General IconGeneral
ManufacturerDelta Electronics
ModelDVP-PLC
CategoryController
Humidity5% to 95% RH, non-condensing
Programming LanguageLadder Diagram (LD), Instruction List (IL), Sequential Function Chart (SFC)
CPU TypeVarious, depending on the specific model within the DVP series (e.g., ES2, EX2, SX2, SA2, EH3, etc.)
Operating TemperatureTypically 0°C to 55°C (32°F to 131°F)
Storage TemperatureTypically -25°C to 70°C (-13°F to 158°F)