1.10. About the error code
See the table below for error codes and details of faults when the îšżrmware is updated through USB memory.
Error
Code
Details of Error code Display Coping strategies
01 Unable to detect USB.
C o n n e c t i o n F a i l 0 1
Disconnect and connect the USB
memory.
02 No Firmware File in USB.
F i l e s N o t F o u n d 0 2
Make sure that the Firmware File is in
the USB memory.
03
Firmware File in USB for unsup-
ported Model name/area.
N o t M a t c h F i r m 0 3
Check the supported Model name/area
for the Firmware File.
04
Failed to obtain individual Firm-
ware information.
C o n n e c t i o n F a i l 0 6
Start the USB Update again.
05
Time Out while obtaining indi-
vidual Firmware information.
C o n n e c t i o n F a i l 0 7
Start the USB Update again.
06
Failed to obtain entire Firmware
information.
C o n n e c t i o n F a i l 0 4
Start the USB Update again.
07
Time Out while obtaining entire
Firmware information.
C o n n e c t i o n F a i l 0 5
Start the USB Update again.
08
Error notiî™°cation received while
requesting Firmware Info.
C o n n e c t i o n F a i l 0 8
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for î™°ve seconds.
09
Time Out while obtaining Firm-
ware information.
C o n n e c t i o n F a i l 0 9
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for î™°ve seconds.
0A
Unable to detect USB for Firm-
ware Download.
C o n n e c t i o n F a i l 0 A
Disconnect and connect the USB
memory.
0B
No Firmware File for Firmware
Download.
F i l e s N o t F o u n d 0 B
Disconnect and connect the USB
memory.
0D
Received value with invalid Pack-
age Version.
C o n n e c t i o n F a i l 0 D
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for î™°ve seconds.
10
No Update Packet received from
CX870 (Time Out).
U p d a t i n g f a i l 1 0
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for î™°ve seconds.
11
Abnormal data in Update Packet
received from CX870 (CRCError).
U p d a t i n g f a i l 1 1
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for î™°ve seconds.
12
Abnormal data in Update Packet
received from CX870 (PacketNo-
Error).
U p d a t i n g f a i l 1 2
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for î™°ve seconds.
73