6159924330 - 08/2020 - 11 -
CVI3 Essential 1 A (24V)
CVI3 Function 1 A (24V)
CVI3 Vision 1 A (24V)
TWINCVI3 2 A (24V)
Power supply
50/60 Hz
Single-phase
eBUS accessories power consumption
24V-1A maximum is supplied from the controller to power eBUS accessories and I/O connectors.
We recommend to use an external power supply box to power all eBUS accessories connected.
Table of maximum current value per accessory
Socket tray 90 mA @ 24V DC
Bit tray 110 mA @ 24V DC
Stacklight 270 mA @ 24V DC
Operator panel 110 mA @ 24V DC
I/O expander 400 mA @ 24V DC
Power consumption calculation
CVI Essential / CVI3Function / CVI3 Vision
The mean apparent power is always ≤ 1 kVA.
@230V < 4.35 A
@110V < 8.7 A
TWINCVI3
The mean apparent power is always ≤ 2 kVA.
@230V < 8.7 A
@110V < 17.4 A
External power consumption
The decision to install an external differential circuit-breaker depends on the type of internal electric network in the
customer’s plant.
This device detects any insulation defect between one of the phases of the network and the earth, immediately stops
the tool by automatic power cutoff and protects the operator from any electric shock.
Should circuit-breakers be installed at the line head, we recommend that you select equipment with the following
specifications:
Single-phased 240V 16A - curve D
Single-phased 110V 32A - curve D.
Controller power consumption: current inlet
Power triangle

Other manuals for Desoutter CVI3 Vision

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Desoutter CVI3 Vision and is the answer not in the manual?

Desoutter CVI3 Vision Specifications

General IconGeneral
BrandDesoutter
ModelCVI3 Vision
CategoryController
LanguageEnglish

Related product manuals