- 22 - 6159924330 - 08/2020
2 white
3 blue
4 black
5 grey
6 pink
Safety-related characteristic data
Value for
1 controller
Value for
2 controllers
PL in accordance with EN ISO
13849-1:2015
PL c PL c
Category in accordance with EN
13849-1:2015
Cat. 1 Cat. 1
PFH in accordance with EN ISO
13849-1:2015 (test every year)
1.11E-07 1.80E-07
B10d 20.000.000 20.000.000
DC 45% 45%
MTTFd [hours] in accordance with EN
ISO 13849-1:2015
HIGH – 93 years HIGH – 93 years
TM in accordance with EN ISO
13849-1:2015
20 years 20 years
Emergency stop, light curtain and RESET connection - category 3 - Level D
Add a safety relay between the controller and the emergency stop.
1 Reset
2 Emergency stop
1 brown
2 white
3 blue
4 black
5 grey
6 pink
Safety-related characteristic data
Value for
1 controller
Value for
2 controllers
PL in accordance with EN ISO
13849-1:2015
PL d PL d
Category in accordance with EN
13849-1:2015
Cat. 3 Cat. 3
PFH in accordance with EN ISO
13849-1:2015 (test every year)
8.57E-09 7.73 E-08
B10d 20.000.000 20.000.000

Other manuals for Desoutter CVI3 Vision

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Desoutter CVI3 Vision and is the answer not in the manual?

Desoutter CVI3 Vision Specifications

General IconGeneral
BrandDesoutter
ModelCVI3 Vision
CategoryController
LanguageEnglish

Related product manuals