3.1
Commissioning
3.1.3
Filii
Bleed Cooling System
2012:
In
accordance
with
the
radiator suppli-
er's specifications
Unit
engine:
In
accordance
with
the
radiator
supplier's specifications
3.1.4 Other Preparations
Check
battery
and
cable
connections,
see
6.7.1
.
Trial
run
-After
the
engine
has
been
prepared,
carry
out
abrief
trial
run
for
approx.
10
minutes,
without
load
if
possible.
During
and
after
the
trial
run
-
Check
the
engine for
leaks.
After
the
engine
has
been
turned
off
-
Check
oil
level
and
top
up
if
necessary,
see
6.1.2.
-
Retension
V-belts,
see
6.5.
Breaking
in
During
the
break-in
phase
-about
200
operat-
ing
hours - check
the
oil
level
twice
a
day.
After
the
engine
is
broken
in,
checking
once
a
day
will
be
sufficient.
In
the
event
of
commissioning
engines
which
have
been
preserved
Carry out
removal
of
preservation
in
accord-
ance
with
Chapter
8.1.
Engine
Operation
('I")
o
o
N
@

Related product manuals