Settings Options:
The Settings options allow for the user to make various programming changes to change how the control
operation aects the customer. See below for detailed information on each next level option.
1. “Decimal Point: If the user programs the Decimal Point to “OFF”, control display will not show a
decimal point on any vend price values. The factory default is “ON”.
2. “Display Time”: If the user programs this value to “MIN”, then minutes only will be shown for the
cycle time. If it is programmed to “MIN+SEC”, then minutes and seconds will be shown.
This also allows other programming changes, involving time, to be made in either minute
increments or minutes & seconds increments, as desired.
3. “Temp Scale”: If the user programs this value to “F”, then the temperatures will be displayed in
Fahrenheit units. If it is programmed to “C”, then the temperature will be in Celsius units.
4. “Sounds”: If the user programs the Sounds to “OFF”, the control will not sound the enunciator at
the end of a dry cycle. The factory default is “ON”.
5. “Password”: If the user programs the password to any value other then 0000, the control will
prompt the user to enter a password (the programmed value) before manual programming
can be accessed. The factory default is “0000” (no password).
a. Note that if the user forgets the Password, it can be reset to factory default (no pass
word), by performing a hard reset on the control. Please refer to the appropriate
section of this manual to understand how to perform a hard reset.
b. The individual digits of the Password can be set by using the “Up” or “Down” buttons
to change the number that is ashing. Once the desired number is chosen for a
single digit, press the “Enter” button to move to the next one.
Once all four desired digits are chosen, the “Enter” button must be held down for 3
seconds to conrm that the complete password should be set.
6. “Central Pay”: If the user programs this value to “ON”, the left and right coin inputs become up
per and lower dryer coin inputs.
Central Pay “OFF” Central Pay “ON”
Left Coin Input Upper Dryer Input
Right Coin Input Lower Dryer Input
A system can then be installed that will register coin inputs per individual dryer remotely from a Central Pay
kiosk. The left and right coin prices must be appropriately programmed. When this option is enabled, the
controller will only display customer prompts for a designated dryer. This designated dryer is determined
when coins are inserted at the Central Pay kiosk.
7. “Language”: The control uses English for the default language of the customer prompts. Al
ternatively, the user can choose Spanish, French, Malay, or Italian for the customer
display prompts. However, all other prompts, such as Manual Programming, USB
Programming and any Error Codes will still display in English.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dexter Laundry DC30X2NC-39AC1X and is the answer not in the manual?

Dexter Laundry DC30X2NC-39AC1X Specifications

General IconGeneral
BrandDexter Laundry
ModelDC30X2NC-39AC1X
CategoryDryer
LanguageEnglish

Related product manuals