Fault# Description Customer Action
F1 The door failed to close and lock
or The door failed to remain locked
during the cycle. Check VFD fault code before turning off .Turn off thepower
to the washer. Check wire connections to door /lock switches.
Check wire connections from switches to controller. Check
P-4 wire connections at PCB controller. Adjust the door lock
mechanism. (See service manual)
F2 The washer tub does not fill
with water within 7 minutes.
The wash cycle will continue.
The F 2 will flash threetimes,
then wait for 30 seconds.
The error will clear at the end
of the cycle. Check VFD fault code before turning off power. Turn of the
power to the washer. Check the operation of the water valves.
Check the incoming water pressure. Check for blocked or
restricted water flow. Check to ensure the drain valve is
functioning properly. This error will occur on 18# washers
when water level is set for high(
the pressure switch in 18#
washer is only one level).
F3 Memory error in controller Check VFD fault code before turning off power. The memory
checksum is wrong. Try to clear the fault with the Palm. Try a
soft Reset of the
controller with the white button. If problem
returns then replace controller.
F4 Washer controller communication
error Turn Power back on to the washer. If the problem returns,
replace the PCB washer controller. If the machine is operating
with an EASY CARD system connected then unplug reader and
turn power back onto machine and if fault reappears on machine
front display replace main PCB controller
F5 Pressure Switch error (only OPL)
- when the high level
senor indicates full but the lower
one indicates empty.
The wash cycle will continue.
The F 5 will flash three times,
then wait for 30 seconds.
The error will clear at the end
of the cycle. Check VFD fault code before turning off power. Check the
pressure switch.(
Ohm out contacts). Check pressure switch
connections to ensure they are all making good contact. Check
the Molex type harness connector to ensure no wire been
pushed out of the Molex type housing that it is shorting.

Table of Contents

Other manuals for Dexter Laundry V-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dexter Laundry V-Series and is the answer not in the manual?

Dexter Laundry V-Series Specifications

General IconGeneral
BrandDexter Laundry
ModelV-Series
CategoryWasher
LanguageEnglish

Related product manuals