DI-600 Operation Manual
Page No.
8
2.10. Weight Unit Conversion
INDICATION FLAG : ( EXPRESS BRIGHT,  SPARKLING )
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1 (8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight
1 2 3 4 5 6 7 8 9 10 11 12
Remarks
Weighing mode
0.000
kg
1.000
kg
Put 1.0kg
Press [lb] key
[ lb]
2.204
Lb
Display in lb
Press [lb] key
[ lb]
1.000
kg
Display in kg
Note: Set the SPEC 19 Bit 0 as 0 to enable this function.
2.11. Set Point Value Setting & S. Memory Recall
System can be set 5 groups of set-point value, each group can be registered 4 points data.
Before be use this function, we should program the group data of set point into memory first.
When the weight exceeds the first point value, the indicator OS1 will be light.
When the weight exceeds the second point values, the indicator OS1 and OS2 will be light.
When the weight exceeds the third point values, the indicator OS1, OS2 and OS3 will be light.
When the weight exceeds the fourth point values, OS1, OS2, OS3 and OS4 will be light.
2.11.1. Set Point Value Setting
INDICATION FLAG : ( EXPRESS BRIGHT,  SPARKLING)
(1) Zero (2) Net (3) STA (4) Count (5) Check (6) MEM (7) OS1 (8) OS2 (9) OS3 (10) OS4
(11) Hold (12) ALM
Indicators
Operation Key Weight
1 2 3 4 5 6 7 8 9 10 11 12
Remarks
Weighing mode 0.000
kg
Press [M][M][M][M]
[M][M]
[M][M]
S.PoInt1
6.000
kg
SM1, SP1 data Set.
SM1 bright
Input value
(Ex: 1.000kg)
[1][0][0][0]
1.000
kg
SP1 Value is 1 kg
Press [Enter] ke
y
[Enter]
S.PoInt2
6.000
kg
SM1, SP2 data Set.
SM1 bright
Input number value
(Example: 2.000kg)
[2][0][0][0]
2.000
kg
SP2 value is 2 kg
Press [Enter] ke
y
[Enter]
S.PoInt3
6.000
kg
SM1, SP3 data Set.
SM1 bright
Input number value
(Example: 3.000kg)
[3][0][0][0]
3.000
kg
SP3 value is 3 kg
Press [Enter] ke
y
[Enter]
S.PoInt4
6.000
kg
SM1, SP4 data Set.
SM1 bright
Input number value
(Example: 4.000kg)
[4][0][0][0]
4.000
kg
SP4 value is 4 kg
Press [Enter] key [Enter]
S.PoInt1
6.000
kg
SM2, SP1 data Set.
SM2 bright
Repeat above
operation
:
:
SM2~SM5 data
Press [Tare] key [Tare]
0.000
kg
Weighing mode
Note: The value of each set point should be assure SP1 less then SP2, SP2 less then SP3,
SP3 less then SP4 and SP4 less then full capacity.