3. Error Message
3.1. Error Message List & Solution
DI-600 will display error message if improper operation is performed or system defect.
No. Display Contents Solution
01 OF
Over Flow, weight is over full
capacity.
Remove some weight form platform.
02 LO
Lower weight, weight value is
lower then limit of display
mask weight.
Add some weight or restart the
indicator
03 nOt Ad
A/D error
Check the A/D board and load cell are
defective or not.
04 zErO Er
Zero Point error, not at zero
point or over start range
Remove weight on platter or restart
the scale, otherwise calibrate it again.
05 Add. OF
Accumulated data over flow Clear the total data and operate again.
06 GrA. OF
Grand Total data over flow Clear the grand total.
If the problems still can not be resolved according to above information, please contact to our
local dealer or Technical Service Dept. of Shanghai Teraoka via the information which described
on manual cover.