27
Weight and Measures Specification (continued):
Spec No. Bit 3 Bit 2 Bit 1 Bit 0
20 Tare Addition
0 = yes
1 = no
Dual Range
0 = multi gross
1 = multi net
Digital Tare
Setting
0 = no
1 = yes
Tare Range
0 = 50% of max
1 = 100% of max
21 Not used Not used Digital Tare
Rounding
0 = tare exactly
1 = round to
nearest
increment
Tare Auto Clear
0 = no
1 = yes
22 Not used Not used Not used Not used
23 Not used Not used Not used Not used
Load Cell Sensitivity Selection (mV/V) 24
Value
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Minimum
3.46
3.00
2.59
2.25
1.95
1.69
1.46
1.27
1.09
0.95
0.82
0.71
0.61
0.53
0.48
0.40
Maximum
4.00
3.46
3.00
2.59
2.25
1.95
1.69
1.46
1.27
1.09
0.95
0.82
0.71
0.61
0.53
0.46
25 Not used Not used Not used Not used
26 Not used Not used Not used Not used
27 Not used Not used Not used Not used
28 Not used Not used Re-zero
Tracking Range
0 = +/- 2%
1 = unlimited
Power-On Start
Range
0 = +/- 10%
1 = unlimited
29 Not used Not used Not used
Enter weight for
Calibration
0 = no
1 = yes
"
""
"
new spec