To change the setting of the Weight & Measurement SPEC if there are some SPEC need to alter.
(Please turn on the span switch when using this process)
OPERATION
DISPLAY
REMARK
PT kg
/kg
Press SPAN
SWITCH
Z1.0 RESET SALES DAILY SPAN SWITCH is on(ENABLE).
[Rezero]+[1][4][2] SPEC 600
XXX
(setting)
XXX
(former)
Enter [1][4][2] while depressing
[Rezero].
XXX:SPEC data
[]
SPEC 601 XXX XXX
[]key only increase specification
count, it does not update SPEC data.
[]
SPEC 600 XXX XXX
[]key only decrease specification
count, it does not update SPEC data.
[6][1][5]
[X]
SPEC 600
SPEC 615
615
XXX
XXX
XXX
It goes to a designed specification
count.
(600~709 is enabled)
[>>] SPEC 615 XXX XXX
[>>] key select SPEC data.
Move cursor right.
[<<] SPEC 615 XXX XXX
[<<] key select SPEC data.
Move cursor left.
[1]
[*]
SPEC 615
SPEC 616
001
XXX
XXX
XXX
[*] key to update specification,
increase specification count.
[2] SPEC 616 002 XXX
[C] SPEC 616 000 XXX Clear the enter data.
[PLU]
* Note 1
Z1.0 RESET SALES DAILY
Store the updated specification and
escape to Z mode.
Note 1: If press [T] key, it does not store the updated specification and escape to Z mode.
* Remark: The Weight in the display window will display the SPEC number. The Unit Price
window will display the new value setting entered. The Total Price window will
display the old value setting. The selection you have made will be highlighted in the
dot matrix display. Please use [] to increase spec count, [] to decrease spec count,