SM100 INTERFACE
40
Before setting the SPEC setting of the scale, please check below.
6.2 SCALE ETHERNET ADDRESS
The main board have a Scale Ethernet Address that is set during production. This address is a
hardware setting for Ethernet communication. But when changing a new main board, the new main
board did not have any this address. If the scale is using Ethernet communication, a Scale Ethernet
Address is needed apart from software IP address. Please take note that the Scale Ethernet Address
can only input once after saving. Please view and note down the Scale Ethernet Address of the old
main board before changing the new main board. Below procedure is to view and input the Scale
Ethernet Address. Please turn on the span switch before proceed.
KEY TO PRESS DISPLAY OPERATION
PT kg
/kg
Go to Z mode Z1.0 RESET SALES Daily At Z mode
[REZERO] +
[0][6][1][2]
ETHER NET ……. ……. Viewing of Ethernet address
For new main board, it can
act as input of the address if
the address shown ……..
Else it would not let you to
input
.
[0][0][0][6][C][0]
[0][0][0][0][2]
[4]
ETHER NET 0006C 0000024 For input only. Enter
Ethernet address e.g.
0006C 0000024
[PLU] Z1.0 RESET SALES Daily Save address and escape to Z
mode. After saving it will
not be able to input again.
[T] Z1.0 RESET SALES Daily Escape to Z mode without
saving.
Power off the scale
Turn off the power and do
the memory clear process.
* IMPORTANT : Please take note that this is a one time setting. It cannot be change after setting
it. Please check the old address and input accordingly. As same internal Ethernet
address in a network may conflict during communication.