Specification List SM-100 V2.00 26 December, 2006
2
nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 12 of 32
SPEC
NO.
SPECIFICATION DESCRIPTION SM-100
175 30 lb to 15 kg Conversion
W
0 Disable 1 Enable
For UK only.
176 Discount Time on Daily Basis
X
0 No 1 Yes
177 Weight Check Function
W
0 No 1 Yes
178 Unit Price Override per PLU
X
0 No 1 Yes
179 Black Bar Sensing Label
X
0 Normal 1 Black Bar Sensing
180 Scroll Message Group
0 Disable 1 Enable
181 Continuos Label
X
0 Disable 1 Enable
182 Character Size for Barcode Data
X
0 Large 1 Small
183 PLU Clear after 10 seconds Time-out
W
0 No 1 Yes
184 Duplicate Unit and Total Price on Label
W
0 No Print 1 Print
Effective when SPEC158
= 1.
185 Weigh PLU Can Use for Non-weigh PLU and Vice Versa Function Key Enable
0 Disable 1 Enable
186 Print $ and Weight Unit on Label
X
0 No Print 1 Print
187 Clear Total Data by Serve
r
0 Both Server and Client 1 Server
188 Tare Decimal Point Left Shift for SM-25 FIS3D
W
0 No 1 Yes
189 PLU Auto Delete
0 No Delete 2 30 Days
1 15 Days 3 90 Days
190 Swap Weight and Unit Price on Receipt
W
0 No 1 Yes
191 Default Item Code Equals to PLU Numbe
r
X
0 No 1 Yes
192 Nutrition Template
W
0 Standard 3 Standard Condensed
For U1 and CA only.
1 Simplified 4 Tabulated
2 Simplified Condensed 5 Tabulated Extra Condensed
193 Nutrition Adjustment Feed
X
Enter value from range 0 to 255
For U1 and CA only.
194 Server IP Address
X
Enter a value between 1 to 254
For Client scale only.