API frames Socket Close Response - 0xC3
Digi XBe 3 Cellular LTE Cat 1 AT&T Smart Modem User Guide
273
Socket Close Response - 0xC3
Description
The device sends this frame in response to a Socket Connect (0x43) frame. Since a close will always
succeed for a socket that exists, the status can be only one of two values: Success or Bad socket ID.
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
format.
Field name Field value Data type Description
Frame type 0xC3 Byte
Frame ID Byte A reference identifier used to match status responses.
Socket ID Byte ID of the socket that has been closed.
Status Byte
0x00 = Success
0x20 = Bad socket ID