Page #216 background image
API frames Transmit (TX) Request: IPv4 - 0x20
Digi XBee3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
216
Field name
Field
value Data type Description
Transmitoptions Byte
bitfield
Bit fields are offset 0
Bit field 0 - 7. Bits 0, and 2-7 are reserved, bit 1 is not.
BIT 1 =
1 - Terminate the TCP socket after transmission is complete
0 - Leave the socket open. Closed by timeout, see TM (IP
Client Connection Timeout).
Ignore this bit for UDP packets.
All other bits are reserved and should be 0.
Payload Variable Data to be transferred to the destination, may be up to 1500
bytes.
UDPis limited to 512 bytes.