EasyManuals Logo

Digi XBee3 XB3M1 User Manual

Digi XBee3 XB3M1
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #219 background imageLoading...
Page #219 background image
API frames AT Command Response - 0x88
Digi XBee3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
219
AT Command Response - 0x88
Description
A device sends this frame in response to an AT Command (0x08) frame. Some commands send back
multiple frames.
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
format.
Field
name
Field
value
Data
type Description
Frame
type
0x88 Byte
Frame ID Byte Identifies the data frame for the host to correlate with a subsequent
ACK. If set to 0, the device does not send a response.
AT
command
Byte Command name: two ASCII characters that identify the AT command.
Status
## Byte 0 = OK
1 = ERROR
2 = Invalid command
3 = Invalid parameter
Parameter
value
Byte Register data in binary format. If the register was set, then this field is
not returned.