UltiMate 3000 Nano and Cap- System Installation and Application
26
No. Description Part No.
1
Nano HPLC Capillary HPLC Monolith. HPLC
1 Solvent lines (analytical) 6030.2548
2 Solvent lines from degasser to proportioning valve
(set of 3 including the appropriate fittings)
6035.2540
3 Connection proportioning valve to working pump head (including fittings) 6035.2514
4 Capillary from working pump head to equilibration pump head (including fittings) 6035.3014 (standard) or 6037.3011 (biocompatible)
5 Capillary from equilibration head to outlet unit (including fittings) 6035.3014 (standard) or 6037.3011 (biocompatible)
6 Inline filter (0.5 µm) in frit holder on outlet unit 6000.0045 (standard) or 6282.0022 (biocompatible)
7 Capillary from pump to flow splitter
Long connection (system with detector)
Short connection (system without detector)
6035.2550
2
(standard) or 6037.2550
2
(biocompatible)
6035.2553
2
(standard) or 6037.2553
2
(biocompatible)
8 Capillary from flow splitter to flow manager switching valve
Standard
Biocompatible
6720.0033
2
6721.0033
2
6720.0034
2
6721.0034
2
6720.0034
2
6721.0034
2
9 Trap column holder (with the appropriate capillaries) and
Trap column
6720.0012
2
160454
2
6720.0012
2
160454
2
------------
163972
2
10 Separation column (The column is connected directly to the switching valve.) 160321
2
160295
2
161409
2
11 Capillary from the separation column to the detector flow cell The flow cell is shipped with appropriate capillaries.
12 Capillary from loading pump outlet to autosampler
Long connection (system with detector)
Short connection (system without detector)
6720.0032
2
(standard) or 6721.0032
2
(biocompatible)
6720.0031 (standard) or 6721.0031 (biocompatible)
13 Capillary from autosampler to flow manager switching valve 6720.0038
2
(standard) or 6721.0038
2
(biocompatible)
14 Sample loop (20 µl) 6820.0018
2
(standard) or 6821.0018
2
(biocompatible)
15 Standard needle (2.4 µl, fused silica) 6820.3010 (standard) or 6821.3010 (biocompatible)
1
The part number refers to the packing unit. For more information, contact your Dionex Sales Representative.
2
These parts are included in the Preconcentration Kit for the related application ( section 8.3, page 65).