Page 19 of 100
Press select button 2 to scroll to next routine.
*"LIT" – LIGHTING CONSERVATION CONTROL ROUTINE)
This function is used to turn the lights off and on during certain periods of the day.
Press select button 4 will enter “ENB#” with the current ENB setting displayed.
ENB# - Lighting Conservation Control Enable Routine
This function is used to disable Lighting Conservation Control "ENB0
" (lights will be on at all
times) or enable Lighting Conservation Control "ENB1" (lights can be set to turn off).
Press select button 4 and the # will begin to flash.
Press select button 2 or 3 to scroll between “ENB0” and “ENB1”.
Press select button 4 with the display showing the setting you wish to use and the display will
return to a solid “ENB#”.
Press select button 2 to scroll to “STRT”.
STRT - Start Lighting Conservation Setting (lights off)
This function is used to set the days and time to start Light Conservation when "ENB 1" is
selected.
Press select button 4 and “DAY” will show on the display.
“DAY” - Day to Start Setting.
This function is used to set the days of the week to start Light Conservation.
Press select button 4 and “xxx#” will show on the display, where xxx will be the
day of the week (i.e. MON, TUE, WED, THU, FRI, SAT, SUN, ALL) and # is 0 =
disable, 1 = enable. With the display showing the day you wish to set press select
button 4. The # will start blinking. Press select button 2 or 3 to scroll between
“xxx0” and “xxx1”. Press select button 4 with the display showing the setting you
wish to use. Display will return to “xxx#”. Press select button 2 to scroll to the next
day to set or press select button 1 to return to “DAY”.
Press select button 2 to scroll to “HOUR”.
“HOUR” - Start Hour and Minute Setting
This function is used to set the hours to start Light Conservation (lamps off).
Press select button 4 and “hhmm” will show on the display, where “hh” is the hour
(military time) and “mm” is the minute. “hh” will be blinking, indicating the hour
setting may be changed. Press select button 2 to scroll from 00 to 23. With the
display showing the hour you wish to start Light Conservation, press select button 4.
“mm” will start blinking, indicating the minute setting may be changed. Press select
button 2 to scroll from 00 to 59. With the display showing the minute you wish to
start Light Conservation, press select button 4. The display will return to “HOUR”.
Press select button 1 to return to “STRT”.
Press select button 2 to scroll to “STOP”.
“STOP” - Stop Light Conservation Setting (lights on)
This function is used to set the days and time to stop Light Conservation.
Press select button 4 and “DAY” will show on the display.
“DAY” - Day To Stop Setting
This function is used to set the days of the week to stop Light Conservation and
can be set in the same manner as Day to Start Setting.
“HOUR” - Stop Hour and Minute Setting
This function is used to set the hours and minutes to stop Light Conservation and
can be set in the same manner as Start Hour and Minute Setting.
Press select button 1 to return to “STOP”.
Press select button 1 to return to “LIT”.
Press select button 2 to scroll to next routine.