PROGRAMMING P SERIES
Page 21 of 100
“DEGX” - Degree Fahrenheit / Celsius Setting Routine ( X is the current setting F or C)
This function is used to set the degree reading to Fahrenheit (DEGF) or Celsius (DEGC).
Press select button 4 and “DEGX”, where the current setting (X) will be blinking. Press select
button 2 or 3 to scroll between DEGF and DEGC.
Press select button 4 with the display showing the setting you wish to use and the display will
return to a solid “DEGX”, or press select button 1 to keep the original setting before returning
to the solid “DEGX” display.
Press select button 2 to scroll to “SETP”.
“SETP” - Set Point Control Routine (Default Temperature 35
0
F / 1.5
0
C)
This function is used to set the average product temperature for initial pull down and reload
recovery.
Press select button 4 and “tt.tx” will show on the display where x is F (Fahrenheit) or C
(Celsius) and tt.t is the degrees.
Press select button 2 to increase or 3 to decrease the number by 1°F or 0.5°C. With the
display showing the set point temperature you wish to use, press select button 4.
Pressing select button 1 while in this submenu will return to the “SETP” prompt and keep the
original “SETP” setting.
Press select button 2 to scroll to “STOR”.
“STOR” - Storage Setting Routine (Default Temperature 60
0
F / 15.5
0
C)
This function is used to set the temperature for product storage and is used when Energy
Conservation is enabled.
Press select button 4 and “tt.tx” will show on display when x is F (Fahrenheit) or C (Celsius)
and tt.t is the degrees.
Press select button 2 to increase and 3 to decrease the number by 1°F or 0.5°C. With the
display showing the storage setting you wish to use, press select button 4.
Pressing select button 1 while in this submenu will return to the “STOR” prompt and keep the
original “STOR” setting.
Press select button 2 to scroll to “DSPX”.
“DSPX” - POS Temperature Display Enable Routine
This function is used to enable the POS Temperature to be displayed following the “ICE
COLD COCA COLA” POS message.
Press select button 4 and “DSPX” will show on the display where x is the current setting.
With “X” blinking, press select button 2 or 3 to scroll between “DSPO” disabled or not
displayed and “DSP1” enabled or displayed. With the display showing the setting you wish
to use, press select button 4.
Press select button 1 to return to “RFRG”.
Press select button 2 to scroll to next routine.
*"BLC1" - BLOCK SELECTION BANK 1 ROUTINE (CON 2 must be enabled - C2 1)
This function is used to set selections which will be blocked during certain periods of the day.
Press select button 4 will enter "ENB#" with # being the current enable setting (0 or 1).
"ENB#" - Blocking Enable Routine
This function is used to disable blocking “ENB0” or enable blocking “ENB1”.
When enabled, active selections will not be allowed to vend on the days and times programmed.
Press select button 4 and the current ENB setting will flash.
Press select button 2 or 3 to scroll between “ENB0” and “ENB1”.
Press select button 4 with the display showing the setting you wish to use.
Display will return to a solid "ENB#".
Press select button 2 to scroll to "STRT".
"STRT" - Start Selection Blocking Routine
This function is used to set the day(s) and time to start selection blocking when blocking is
enabled (“ENB1”).
Press select button 4 and "DAY" will show on the display.
"DAY" - Day of Week Start Setting