Introduction XR150FC/ XR550FC Users Guide 7
Special Fire C mma d Ce ter Displays
Asyou use your system, you occasionally see a display that asksyou
to enter a code or that d escribes a condition on the system. Below
are some examples of the d isplays:
ALARM
A 24-hour zone (for example Àre or panic) or an armed burglary
zone has been tripped. Your system may sound bells or sirens.
ALARM n o T SEn T ( Bu r glary Keypad)
The alarm signal was not sent to the central station because a user
code was entered to disarm the system before the alarm signal was
sent to the central station.
ALARM CAn CELLED ( Bu r gl ary Key pad)
An Alarm Cancel signal was sent to the central station because
a user code was entered after an alarm was sent to the central
station.
SI LEn CED
An Alarm Silence has been performed to turn off the notiÀcation
appliances. Zone names are displayed on the bottom line of the
keypad display.
SUPVSRY ( SUPERVI So RY)
A Supervisory type zone alarm has occurred. The zone name is
displayed on the bottom line of the keypad display.
TRo UBLE
There is a problem with a protection device or system component.
This display is accompanied by a description of the problem.
En TER Co DE
The system requiresyou to enter your user code. User codescan be
required for turning your system on (arming), turning your system
off (disarming), and many other functions.
As you enter your user code, the keypad display shows an asterisk
(*) in place of each digit pressed. This keeps others from seeing
your user code on the display as it is entered.
TRY AGAI n r I n VALI D Co DE
The user code you have entered is not recognized by the system.
Check the user code and try again.
I n VALI D PRo FI LE
All user codes have a prle that allow the user to only access
certain functions. When users attempt functions outside their
authority, the INVALID PROFILE message displays.
I n VALI D AREA
A user has attempted a door access for an area they are not
assigned.
I n VALI D TI ME
Auser code assigned to a speciÀc schedule is entered outside of the
valid schedule. See Schedules and User Codes.
ARMED AREA
Auser hasattempted a door access to an armed area to which they
do not have arming and disarming authority.