System Setup XR150FC/ XR550FC User’s Guide 15
User Pro¿les
Change User ProÀles, that deÀne the authority of each user code
in the system. Several characteristics deÀne the authority of each
User ProÀle within the system.
ProÀle Number - Each proÀle may be assigned a unique number
from 1 to 99.
ProÀle Name - Each proÀle may be assigned a 16-character name.
The ProÀle Number is the default name.
Arm or Disarm Areas - Each proÀle may be assigned speciÀc areas
of the system for arming and disarming. When proÀles 1 to 98 are
created, NO areas are assigned b y default. The default for proÀle
99 is ALL areas assigned. ProÀle 99 is predeÀned in the system by
the factory.
Access Areas - Each proÀle may be assigned door access area
assignments. Default for proÀle 1 to 98 is NO areas assigned.
Default for proÀle 99 isALL areas assigned. ProÀle 99 is predeÀned
at the factory.
Output Group Assignment - Each proÀle may be assigned an output
group number from 1 to 10. Default for proÀle 1 to 98 is NO output
group assigned. Default for proÀle 99 is output group 10. Your
system may by programmed to turn on an output group at certain
keypads when door access occurs.
User Menu Assignments - Each user proÀle may have any of the
menus assigned to it as shown in the User ProÀle Record below. The
User ProÀle Record lists the user menu proÀle assignments and the
system functions users are allowed to access based on the proÀle
numbers assigned to their codes.
Alwaysmake sure that at least one administrator in your system has
a proÀle with all authorities and all areas.
User Pro¿les Reference
Me u Display Privilege
ARM NO YES Arm
DIS NO YES Di sarm
ALM SLNC NO YES Alarm Silence
SNSR RST NO YES Sensor Reset
LOCKDOWN NO YES Lockdown
DOOR LOCK/UNLOCK NO YES Door Lock/Unlock
DOOR ACS NO YES Door Access
ARM AREA NO YES Armed Areas
OUTPUTS NO YES Outputs ON/OFF
FAVORITES F01- F20 Z-Wave Favorites
ZN STATS NO YES Zone Status
BYPAS ZN NO YES Bypass Zones
ZONE MON NO YES Zone Monitor
SYS STAT NO YES System Status
SYS TEST NO YES System Test
PROFILES NO YES User Pro¿les
USR CODE NO YES User Codes
SCHEDULS NO YES Schedules
TIME NO YES Time
DIS EVNT NO YES Display Events
SERV REQ NO YES Service Request
FIRE DRILL NO YES Fire Drill
EXTEND NO YES Extend Schedules
TEMP CODE NO YES Temporary User Code
ANTI PASS NO YES Anti-Passback
ACCESS SCHEDULES Sch. 1-99 Allow: Shift/Time Access
RE ARM DLY 0 – 720 Re-Arm Delay
SEC LANGUAGE NO YES Preferred Language