5-18
EN
5.6.1 Power connection
NOTE
All system wiring and power connections must be made to ABYC
standards.
The negative terminals of all batteries must be connected together.
Refer to ABYC E-11 – AC and DC Electrical Systems on Boats
Figure 5-17.
All system connections are made from the Electric Actuator harness
bundle, which has the following connections:
1. 12V power
a. +ve (red)
b. –ve (black)
2. Communication bundle
a. CAN1
b. CAN2 (optional on single-engine systems)
c. CAN3 (for engine RPM)
d. Ignition sensing (purple)
5.6 Electrical connections
5.6.1.1 Planning your 12V power connections
Figure 5-18 shows a sample power schematic. For each actuator in your
system, you will need the following items (not included with your
installation kit):
A 12V DC power source capable of supplying 40A peak current during
aggressive use.