RV So Start Accessory Installation
8.4.9 Attaching the harness wires
WARNING: Electric shock hazard.
There is a risk of electrical shock from the energy
stored in the capacitors. Wait for five minutes aer
the shutdown of equipment before performing
any installation activity. Failure to obey this warning
could result in death or serious injury.
qq
ww
64 Removing the factory compressor wires
q
Wrapped wires
w
Foam shroud
1. Using a multimeter, confirm that the capacitor is fully
discharged.
2. Remove the red and white factory compressor wires
from the capacitor. If necessary, trace the white wire
from the compressor to the capacitor to confirm
which is the correct white wire.
3. Using approximately 6 in. of electrical tape, secure
the wires together.
4. Tuck the wires below the EPP foam shroud next to the
capacitor.
qq
ww
65 Attaching the device supply harness wires
q
HERM terminal
w
COM terminal
5. Attach the red wire to the HERM terminal.
6. Attach the white wire to the COM terminal.
8.4.10 Reattaching the capacitor lid and
securing the wires
qq
ww
66 Lid and putty
q
Capacitor lid
w
Putty