14
2358-065 Issued 7-19
Version E
34
33
32
31
30
29
28
27
26
25
24
23
22
21
14
15
16
17
18
19
20
13
12
11
10
9
8
7
6
5
4
3
2
1
ON
1
0
BOARD ADDRESS
0
9
8
7
6
5
4
3
2
1
NC
OUTPUT
RELAY
NO
NC
ALARM
RELAY
NO
NC
AUX
RELAY
NO
ENT
RESET
2358-010
RF
DATA
RF
SECURE
RF
STATUS
CODE
SENT
CODE
GOOD
CODE
BAD
3.2 Board Addresses 3 - 10 Communication Line HARDwiring
NC
NO
RING
ON
CLK
SEN
SPK
VOL
FEED
BACK
RS 232
ELEVATOR
12345 67891011121314
1
2
3
MIC
VOL
OFF
KEYPAD
321
321
321
MASTER
CODE
16AC16ACBAT
1NO1NC1C
2RY2C
AZIMC
5VDCIMDSPKRCOMMICPSWCGNDPHONE
12 34 201918171615141312111098765
NO NC C
1830 Series
Access Control
System Board
Relay 2
Wiegand 2
Auxiliary Terminal
Main Terminal
Relay 0
Relay 1
Board Address 3
Central Office
phone line -
touch tone,
loop start.
Switch closure across
terminals 4 & 6 will
activate relay 1 for its
programmed strike time.
Important Note: Relay 2 is used to
control tracker expansion board
addresses 3-10, Relay 1 or Relay 0 can
be used as the Primary Relay that will
open a visitor door or gate when the
resident pushes “9” on their telephone.
Tracker expansion boards connected to Wiegand 2
will activate Relay 2 in the access control system.
Main Door/Gate
Relay 1 or Relay 0
Auxiliary
Terminal
Black #9-Com
White #8-Data 1
Green #7-Data 0
Black #27
White #28
Green #29
Brown #19
Blue #17
Red #10
Tracker Expansion
Board “Busy” #10
Brown #13
Blue #14
To Board Addresses 4 thru 10
24 tracker expansion boards can be connected to Relay 2/Wiegand 2. If more than 24 tracker expansion boards are desired, see next page.
Note: Terminals
can be removed
from board for
easy wiring.
Ground #32
NO
Com
Ground
12 GA. Wire
Use 6 conductor stranded with overall shield. 18 - 22 gauge.
ONLY use 18 gauge when wiring more than 8 boards.
DO NOT connect shield to 2358-010 board common.
DO NOT use twisted pair.
Communication line to additional boards are
connected in parallel. Allows “teeing” of
communication cable for optimal cable routing.
Aux
Power
Power #33
Power #34
Board Power
16.5 VAC, 20 VA
#10 connects
ONLY to tracker
expansion boards
Maximum HARDwire run between tracker expansion boards is 4000 ft total, but no more than 2000 ft between any two
boards or from the access control system. See section 2.
DO NOT use twisted pair wire with wiegand output format.
Auxiliary terminal power transformer on access control system board must be connected. Otherwise, RS-232, elevator control
and wiegand inputs will not function.
Proper grounding is required! Ground wire should be a minimum 12 AWG.
Notes:
Board address must be set for EACH BOARD wired, see section 1.6.
End-of-Line Jumper has to be used on last board, see section 1.8.
Power, access control devices, door or gate control, aux and alarm
outputs, door and reset switches, request to exit, etc. wiring is not
shown, see section 3.5-3.8.
Gate operator data wiring is not shown, see section 3.10.
Important Wireless Note:
Wireless kits ARE NOT
wired like this. Refer to
wireless instructions with
the wireless kits when using
wireless communication.
Relay 2 Jumper
set to Normally Open
NC
NO
Relay 2/Wiegand 2 to Tracker Expansion
Board Terminal Connection Numbers
Auxiliary Terminal Tracker Terminal
Black #9-Com
White #8-Data 1
Green #7-Data 0
#27
#28
#29
Main Terminal Tracker Terminal
Brown #13-Com
Blue #14-N.O.
#19
#17
Tracker Terminal Tracker Terminal
Red #10-Busy #10
When using multiple tracker boards:
Note: See
section 3.5-3.8
to wire board
options.
1830’s relay
strike time
MUST be
programmed
to “00”.

Other manuals for DoorKing 1830 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DoorKing 1830 Series and is the answer not in the manual?

DoorKing 1830 Series Specifications

General IconGeneral
BrandDoorKing
Model1830 Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals