ON
1
0
BOARD ADDRESS
0
9
8
7
6
5
4
3
2
1
NC
OUTPUT
RELAY
NO
NC
ALARM
RELAY
NO
NC
AUX
RELAY
NO
ENT
RESET
2358-010
RF
DATA
RF
SECURE
RF
STATUS
CODE
SENT
CODE
GOOD
CODE
BAD
Local
Alarm
Separate
Alarm
Power
External Alarm Reset
Door Contact Switch
Integral Mode
(Programming Step 16)
Dry relay contacts connect
to existing alarm system.
Terminals-#23 & #24 Alarm Relay Jumper
Terminals-#21 & #22 Aux Relay Jumper
3.6 Alarm Wiring Options at Access Point
Board Address
MUST be set.
See section 1.6.
Note: Relay contacts (21-22; 23-24) are rated at 1A 30V
maximum and can be set for Normally Open (N.O.) or
Normally Closed (N.C.) operation.
Set Alarm Relay
jumper typically (NO).
Set Auxiliary Relay jumper typically (NO).
#8-Common
#8-Common
#21-Auxiliary Relay
#23-Alarm Relay
#24-Alarm Relay
#33 - 16.5 VAC Power
#32 - Ground Required
#34 - 16.5 VAC Power
#22-Auxiliary Relay
#16-Reset Alarm Input
#15-Door Ajar Input
Board Power
16.5 VAC, 20 VA
Required
18 GA. Wire 100 ft max
16 GA. Wire 200 ft max
Note: Terminals
can be removed
from board for
easy wiring.
Door
Door Fr
a
me
Door Contact Switch
Bypass Mode
(Programming Step 16)
MUST be connected to
existing alarm system.
#23-Alarm Relay
#24-Alarm Relay
Door
Door Fr
a
me
Switch Closed:
Door Closed
N.C.
Com
Switch Open:
Door Open
N.C.
Magnet
SPST (NO)
SPST (NO)
Com
Switch Closed:
Door Closed
N.C.
Com
Switch Open:
Door Open
N.C.
Magnet
SPST (NO)
SPST (NO)
Com
Note: Input for door contact switch is factory set at
0 for normally Open (Circuit Open - CO) but it can
be set for normally Closed (Circuit Closed - CC) by
programming step 8, set to 1 if required.
PRESS
to RESET
Do Not Connect
To A Receptacle
Controlled By A
Switch.
Wire polarity
does not matter.
Important Note: Communication line
(sections 3.2-3.4) is NOT shown.