22
2358-065 Issued 7-19
Version E
Output Relay Jumper “NO”
34
33
32
31
30
29
28
27
26
25
24
23
22
21
14
15
16
17
18
19
20
13
12
11
10
9
8
7
6
5
4
3
2
1
ON
1
0
BOARD ADDRESS
0
9
8
7
6
5
4
3
2
1
NC
OUTPUT
RELAY
NO
NC
ALARM
RELAY
NO
NC
AUX
RELAY
NO
ENT
RESET
2358-010
RF
DATA
RF
SECURE
RF
STATUS
CODE
SENT
CODE
GOOD
CODE
BAD
LIMIT
LIMIT
PA RT
TIME
DELAY
REV SENSE
CLOSE
REV SENSE
OPEN
1
ON
2 3 41
ON
2 3 4 5 6 7 8
NO NC
EXIT
LOOP
REVERSE
LOOP
GATE FORCED
20 19
18 17
16 15
14 13
12
11 10
9
8
765
4
3
2 1
4402-010
3.10 Gate Operator Data Wiring - Optional Control Wiring
Each tracker expansion board can report data about gate operators SPECIFIC activity to the access control system. Two (2) DoorKing gate
operators; a slide, swing or overhead gate operator and a barrier gate operator can be “Tracked”. See section 5.3 for a list of the events that
can be reported (Tracked). The gate operators can also be controlled (Opened and closed) if desired by wiring the red dashed wires along with
the black wires in the diagrams. Choose your specific gate operator model from the 6 diagrams shown on the next 3 pages. Only DoorKing
gate operators shown in the 6 diagrams will function. DO NOT wire the tracker expansion board to a third party gate operator.
REVERSE
SENSITIVITY
TIME
DELAY
POWER
1
ON
2 3 4 5 6 7 81
ON
2 3 4 5 6 7 8
NC NO
UP
LOOP
DOWN
LOOP
1234567 8 9 10 11 12 13 14
1601-010
Output Relay Jumper “NO”
34
33
32
31
30
29
28
27
26
25
24
23
22
21
14
15
16
17
18
19
20
13
12
11
10
9
8
7
6
5
4
3
2
1
ON
1
0
BOARD ADDRESS
0
9
8
7
6
5
4
3
2
1
NC
OUTPUT
RELAY
NO
NC
ALARM
RELAY
NO
NC
AUX
RELAY
NO
ENT
RESET
2358-010
RF
DATA
RF
SECURE
RF
STATUS
CODE
SENT
CODE
GOOD
CODE
BAD
Data
Terminal
3 - Data
2 - Busy
1 - Com
1601, 1602, 1603 Barrier Gate Operators
1150 Overhead Gate Operator
25
26
25
26
3From 3 Data
From 2 Busy
From 1 Com
4
5
13
13
14
12
1
2
5
5
Jumper 5-11
Use 6 conductor,
stranded with overall
shield. 18-22 gauge.
DO NOT use twisted
pair.
Use 6 conductor,
stranded with overall
shield. 18-22 gauge.
DO NOT use twisted
pair.
Dashed lines are ONLY
required if the tracker
expansion board is to
OPEN the vehicular
overhead gate when a
valid access code has
been received (Output
relay jumper is set to
normally open).
Dashed lines are ONLY
required if the tracker
expansion board is to
RAISE the barrier arm
when a valid access
code has been
received (Output relay
jumper is set to
normally open).
Black lines are for gate operator data wiring ONLY.
Black lines are for gate operator data wiring ONLY.
3 to Data Term 3
4 to Data Term 2
5 to Data Term 1
13 to 14
14 to 5
1 to 10
2 to 11
5 to 1
12 to 14