SECTION 4 - TECHNICAL INFORMATION
4-29
SmartDate 5 08/08
Shuttle Calibration - SmartDate 5s
A Handing micro-switch determines if the printer is a left hand or a right hand
printer.
The switch is situated under the position for the left hand module and is only
activated when the module is a left hand.
Once this is established the printer will move the shuttle carriage to the
appropriate datum position.
Shuttle Printer LH Shuttle Printer RH
Datum Micro Switches