EasyManua.ls Logo

Dover markem-imaje SmartDate 5 - Communication Problems; Communications Do Not Work

Dover markem-imaje SmartDate 5
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SECTION 5 - TROUBLESHOOTING
5-37
SmartDate 5 06/08
5.15 Communication Problems
5.15.1 Communications Do Not Work
If DCP communication fails between SmartDate 5 and CoLOS Control, check the
following:
Ethernet Communications
Is the correct IP address configured?
Is the correct IP Subnet mask configured?
Is the DCP Actor name (Device Network ID) on the SmartDate 5 the same as
Device Network ID on CoLOS Control?
Are the Ethernet cable or connectors faulty?
RS-485 Communications
Is the SmartDate 5 serial Port 1configured correctly? (DCP RS-485)
Is Serial Port 1 Baud Rate configured correctly? This must be the same as the
setting on CoLOS Control.
Is Serial Port 1 CimComms Node configured correctly? This must be the same
as the Device setting on CoLOS Control.
Is the DCP Actor name (Device Network ID) on the SmartDate 5 the same as
Device Network ID on CoLOS Control?
Is the correct communications cable connected between the SmartDate 5
Serial port and the CimLan Communications card?

Table of Contents

Related product manuals