2. Prepare and install the 20-1618 Power Cable.
a. Remove the connector from CN12 of the DPC interface board. Attach the gray and orange
wires from the power supply cable (P/N: 20-1618) to the connector. Put the assembled
connector back on to CN12 of the DPC interface.
NOTE: Connect the Gray wire to one terminal screw and the orange to the other. Polarity is
not important.
b. Put the Molex connector end of the 20-1618 cable through an open knockout hole in the
bottom of the terminal.
c. For PV200 installation, connect the Molex end to an available connector of the Petro-Net
Power board (J6, J7 or J8) (for PV300E installations, connect the Molex connector to the PCM
plug on the front of the power supply assembly. See the illustration below).
M1700 FSC3000 Installation Manual | Dover Fueling Solutions 56