Dr.coffee F10 - Steam Thermo-Block NTC Error; Coffee Thermo-Block Heating Overtime; Steam Thermo-Block Heating Overtime

Dr.coffee F10
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev 0.0
Dr.coffee 产品维修手册 36
9.1.5 Steam Thermo-block NTC Error
Showing on the Screen Cause Solutions
Stea
m
Ther
mo-
bloc
k
NTC
Erro
r
a) The temperature of the thermos-bl
ock
exceeds settled value
b)
Electronic fault between sensor and
master
c) Sensor damaged
Replace the fuse of thermos-block;
Replace the NTC sensor;
Replace thermos-block group
9.1.6 Coffee Thermo-block Heating Overtime
Showing on the Screen
Cause
Solutions
Coff
ee
Ther
mo-
bloc
k
Heat
ing
Over
time
a) The temperature of the thermos-
block
exceeds settled value and fuse burn out
b) sensor damaged;
c) Thermo-block damaged
Replace the fuse of thermos-block;
Replace the NTC sensor;
Replace thermos-block group
9.1.7 Steam Thermo-block Heating Overtime
Showing on the Screen
Cause
Solutions
Stea
m
Ther
mo-
bloc
k
Heat
ing
Over
time
a) The temperature of the thermos-
block
exceeds settled value and fuse burn out
b) sensor damaged;
c) Thermo-block damaged
Replace the fuse of thermos-block;
Replace the NTC sensor;
Replace thermos-block group