Sensor warm-up acceleration
Sensor warm-up acceleration
There is a function available for accelerating the warm-up procedure for selected EC
sensors. The function shortens the time taken until the unit is ready to make
measurements, i.e. the time taken to save the display and alarm evaluation of the
measurements. The time to activate the calibration is not changed.
In order to use the sensor warm-up acceleration function in the Dräger X-am 5000,
at least one sensor suitable for the purpose must be fitted and registered in the unit
using the Dräger CC-Vision PC software.
After that, activate the function by ticking the "Accelerated warm-up" checkbox
("Device" menu) and updating the device data with Dräger CC-Vision.
NOTICE
A selection menu for activating the process will only be displayed after the device is
restarted by plugging in a power pack.
Restart the device by plugging in a
power pack.
All the display segments, including the
visual, audible and vibration alarms,
are activated for a short time.
The software version is displayed.
The instrument performs a self test.
The sensor warm-up acceleration
menu is displayed.
The steps in the selection menu are
limited by a 25-second time-out, which
then changes to the standard setting
of unaccelerated warm-up and
proceeds with the device start-up
procedure.
It is necessary to select between two
times for the sensor warm-up
acceleration,
the shortened time achievable as a re-
sult of the warm-up acceleration,
the unshortened time required by the
installed sensors to save the measure-
ment display (measurement does not
flash any more).
Select the shortened warm-up time
with the button and confirm it with
the button.
The function for entering the password
is called up.
Enter the digits with the button and
confirm with the button.
05523999_01.eps
5:00
120:00
05623999_01.eps
001
OK
OK